product

 Home » Products » Switching power supply » DR-120-24 DIN Rail 120W 24V Switching Power Supply

DR-120-24 DIN Rail 120W 24V Switching Power Supply

For AC power supply input global
Protection characteristics: short circuit/overload/pressure
Air cooling
Can be installed DIN standards guide TS-35/7.5 or 15
Has the boot display (light emitting diode (led)
100% full load and machine test
Working frequency 47-63KHz
One year warranty

odel DR-120-12 DR-120-24 DR-120-48
output Dc output voltage 12V 24V 48V
Output voltage tolerance ±2% ±1% ±1%
Rated output current 10A 5A 2.5A
Output current range 0-10A 0-5A 0-2.5A
Output power 120W 120W 120W
Ripple and the noise 80mVp-p 80mVp-p 100mVp-p
Dc voltage adjustable scope 12-14V 24-28V 48-53V
Start, rise time 500 ms, 70 ms / 230 VAC carrying 500 ms, 70 ms / 115 VAC carrying
Keep time 36 ms / 230 VAC32ms / 115 VAC carrying
input Input voltage range 88~132 VAC/176~264VAC47~63 Hz;The switch choice 248~370VDC
Exchange input current 2.6 A/115 V 1.6A/ 230 V
efficiency 80% 84% 85%
Impulse current Cold start current  20A/115V 40A/230V
Leakage current <3.5mA/240VAC
Protection characteristics The switch choice 105%~150%
Protection way: constant current limiting automatic recovery
Overvoltage protection 120%~135%
Protection way: cut output, restart
High temperature protection 85ºC±5ºC(TSW1) 90ºC±5ºC(TSW1) 90ºC±5ºC(TSW1)
Protection way: cut output, temperature down automatically restored
environment Working temperature, humidity -10ºC~+60ºC;20%~90 %RH
Keep temperature, humidity -20ºC~+85ºC;10%~95 %RH
Vibrate resistance 10~500Hz,2G 10min./1 cycle time, 60 minutes, the axis
security Compression sex 3: KVAC between input and output and input and output KVAC: 1.5 to 0.5: KVAC
Insulation resistance Between the input and output, the input and output, and ground: 100 M / 500 VDC Ohms
standard Safety standards UL508,UL60950-1,TUV EN60950-1
EMC standard EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-2(EN50082-2)
other weight 0.79Kg
packaging 20pcs/16.5Kg/1.1CUFT
note 1. All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25 ºC conditions measuring income value.
2. Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement.
3. Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate.
4. The power to consider as a device installed in final equipment, this equipment must be to make sure it's EMC index.
 
1. All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25 ºC conditions measuring income value.
2. Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement.
3. Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate.
4. The power to consider as a device installed in final equipment, this equipment must be to make sure it's EMC index.
 
Dr-120-24 DIN Rail 120W 24V Switching Power Supply

Welcome to our website! Please send your words at any time in the following form and ask us, we will contact you and provide you with the corresponding service as soon as possible. Please write in English.

S-150-24 High Quality 150W 24VDC SMPS Switching Power Supply

Learn More

S-1000-24 High Quality 1000W 24VDC SMPS Switching Power Supply

Learn More

Mini Size 24V 2.5A 60W Ms-60-24 AC to DC 110V/220V Transformer SMPS Switch Power Supply

Learn More

S-200-5 High Quality 1000W 24VDC SMPS Switching Power Supply

Learn More